Applies to:
The optical cable is designed for laying in the ground, including swamps and shallow non-navigable rivers, in cable ducts, pipes, trays, blocks, tunnels, collectors, bridges and overpasses, between buildings and structures, inside buildings.
Cable Structure:
The cable contains a central optical module with freely laid fibers. The free space in the optical module is filled with a hydrophobic gel. The armor of steel wires is spirally applied to the central optical module. The free space between the wires is filled with a hydrophobic gel. The shell is made of medium density polyethylene.
-1. Polyethylene sheath
-2. Optical module
-3. Steel wire armor
-4. Optical fiber
-5. Hydrophobic gel inside modular
Construction Details:
Number of OM in the cable |
Up to 16 |
Up to 24 |
Diameter of cable, mm |
9,5 |
9,7 |
Cable weight, kg / km |
153,4 |
155,6 |
Operating Parameters:
Working temperature |
-45 С...+70 С |
Mounting temperature |
-30 С...+50 С |
Transport and storage temperature |
-60 С...+70 С |
Minimum bending radius |
not less than 20 cable diameters |
Life time |
25 years |
Features:
Applies to:
The optical cable is designed for laying in the ground, including swamps and shallow non-navigable rivers, in cable ducts, pipes, trays, blocks, tunnels, collectors, bridges and overpasses, between buildings and structures, inside buildings.
Cable has excellent protection against rodents
Cable Structure:
The cable comprises a core of a modular design with a central power element of a dielectric rod around which optical modules with freely laid fibers are twisted. The free space in the optical modules and in the cable core is filled with a hydrophobic gel. An intermediate shell of medium density polyethylene is applied to the core. Armor made of steel wires is helically superimposed on the intermediate shell. The free space between the wires is filled with a hydrophobic gel. The shell is made of medium density polyethylene.
-1. Outer sheath
-2. Steel wire armor
-3. Polyethylene Intermediate Sheath
-4. Hydrophobic gel
-5. Central power element (fiberglass rod)
-6. Optical module
-7. Optical fiber
Construction Details:
Number of OM in the cable |
Up to 16 |
Up to 36 |
Up to 48 |
Up to 60 |
Up to 72 |
Number of optical modules |
4 |
6 |
4 |
5 |
6 |
Number of fibers in the module |
4 |
6 |
8 |
12 |
12 |
Tensile force |
7кН |
||||
Diameter of cable, mm |
13,8 |
14,1 |
14,1 |
14,8 |
14,8 |
Cable weight, kg / km |
228,3 |
240,1 |
252,1 |
260,8 |
294,8 |
Tensile force |
20кН |
||||
Diameter of cable, mm |
13,8 |
14,1 |
14,1 |
14,8 |
14,8 |
Cable weight, kg / km |
228,3 |
240,1 |
252,1 |
260,8 |
294,8 |
Operating Parameters:
Working temperature |
-50 С...+70 С |
Mounting temperature |
-30 С...+50 С |
Transport and storage temperature |
-60 С...+70 С |
Minimum bending radius |
not less than 20 cable diameters |
Life time |
25 years |
Features: