Applies to:
The optical cable is designed for laying in cable ducts, pipes, trays, blocks, tunnels, collectors, bridges and overpasses, into the ground, between buildings and structures, and also inside buildings.
Cable has excellent protection against rodents
Cable Stucture:
The cable contains an optical module with freely laid fibers.
The free space in the optical module is filled with a hydrophobic gel.
Above the module is an armor made of corrugated steel tape and a medium density polyethylene shell. The free space under the corrugated tape is filled with a hydrophobic gel. In the cable sheath, diametrically opposed are two steel wires, which serve as power elements.
-1. Outer sheath
-2. Corrugated steel strip armor
-3. Optical module
-4. Optical fiber
-5. Steel wire
-6. Hydrophobic gel
Construction Details:
Number of OM in the cable |
Up to 12 |
Up to 16 |
Up to 24 |
Diameter of cable, mm |
8,3 |
8,5 |
8,8 |
Cable weight, kg / km |
77,2 |
79,2 |
86,1 |
Operating Parameters:
Working temperature |
-50 С...+70 С |
Mounting temperature |
-30 С...+50 С |
Transport and storage temperature |
-60 С...+70 С |
Minimum bending radius |
not less than 20 cable diameters |
Life time |
25 years |
Features:
Applies to:
The optical cable is designed for laying in cable ducts, pipes, trays, blocks, tunnels, collectors, bridges and overpasses, into the ground, between buildings and structures, and also inside buildings.
Cable has excellent protection against rodents
Cable Structure:
The cable comprises a core of a modular design with a central power element of a dielectric rod around which optical modules with freely laid fibers are twisted. The free space in the optical modules and in the cable core is filled with a hydrophobic gel. An intermediate shell of medium density polyethylene is applied to the core. Armor made of corrugated steel tape is placed longitudinally on the intermediate shell. Between the intermediate shell and armor a hydrophobic gel is laid. The shell is made of medium density polyethylene.
-1. Outer sheath
-2. Corrugated steel strip armor
-3. Polyethylene Intermediate Sheath
-4. Optical module
-5. Optical fiber
-6. Central power element (fiberglass rod)
-7. Hydrophobic gel
Construction Details:
Number of OM in the cable |
Up to 16 |
Up to 36 |
Up to 48 |
Up to 60 |
Up to 72 |
Number of optical modules |
4 |
6 |
4 |
5 |
6 |
Number of fibers in the module |
4 |
6 |
8 |
12 |
12 |
Tensile force |
2,7кН |
||||
Diameter of cable, mm |
13,8 |
14,1 |
14,1 |
14,8 |
14,8 |
Cable weight, kg / km |
228,3 |
240,1 |
252,1 |
260,8 |
294,8 |
Operating Parameters:
Working temperature |
-50 С...+70 С |
Mounting temperature |
-30 С...+50 С |
Transport and storage temperature |
-60 С...+70 С |
Minimum bending radius |
not less than 20 cable diameters |
Life time |
25 years |
Features: