Drop

Fiber-optic cables

Fiber optic communication cable:

Documentation

Applies to:

For air suspension on the supports of communication lines, lighting (with the exception of poles of high-voltage power lines), between buildings and structures, as well as in tunnels when entering buildings.

 

Cable Structure:

The cable contains an optical module with freely laid fibers.

The free space in the optical module is filled with a hydrophobic gel.

Two dielectric rods are used as power elements. On the optical module and the power element, a medium density polyethylene shell is applied.

 

-1.Polyethylene jacket

-2.Hydrophobic gel inside modular

-3.Optical fiber

-4.Optic module

-5.Power elements

 Construction details:

Extras. tensile load, kN

1,3

1,7

Number of OM in the cable

 Up to 8

Up to 12

Overall dimensions, mm

8,8x4,0

9,3x4,8

Cable weight, kg / km

35

48

 

Operating parameters:

Transport and storage temperature ° C

-50 С...+60 С

Operating temperature, ° C

-60 С...+70 С

installation temperature

Up to -10

Allowable tensile force, kN

Up to 1,7

Permissible tensile force, kN / 100mm

3

Life time

25 years

 

Features:

  1. May be immune to electric fields
  2. It is possible to manufacture an outer sheath of non-flame retardant polyethylene
  3. The power element is made of 2 x glass plastic rods or wires
  4. It is possible to manufacture any lengths according to the customer's request
  5. Marking of the running meter with accuracy not worse than 1% 6. Warranty 2 years from the date of delivery

Fiber optic communication cable:

Documentation

Applies to:

It is used for air suspension on supports of communication lines, lighting (with the exception of poles of high-voltage power lines), between buildings and structures, as well as in tunnels when entering buildings.

 

Cable Structure:

The cable contains an optical module with freely laid fibers. The free space in the optical module is filled with a hydrophobic gel. Two dielectric rods are used as power elements. On the optical module and the power element, a medium density polyethylene shell is applied.

 

-1. Outer shell

-2. Optical module

-3. Hydrophobic aggregate

-4. Optical fiber

-5. Power elements

 

 Construction details:

Extras. tensile load, kN

0,5

Number of OM in the cable

Up to 12

Overall dimensions, mm

5,7

Cable weight, kg / km

32

 

Operating parameters:

Transport and storage temperature ° C

-50 С...+60 С

Operating temperature, ° C

-60 С...+70 С

installation temperature

Up to -10

Allowable tensile force, kN

Up to 1,7

Permissible tensile force, kN / 100mm

3

Life time

25 years

 

Features:

  1. May be immune to electric fields
  2. It is possible to manufacture an outer sheath of non-flame retardant polyethylene
  3. The power element is made of 2 fiberglass rods or wires
  4. It is possible to manufacture with an outer jacket of trekking-resistant polyethylene
  5. It is possible to manufacture any lengths according to the customer's request
  6. Marking of the running meter with accuracy not worse than 1%